Flow detectors
Serie EMPO
Flow testing for components intended for the automotive, pneumatic, hydraulic, and domestic sectors.
Measure flow in supply or capture.
Programmable minimum/maximum pressure and minimum/maximum flow thresholds.
Programmable maximum pressure and flow.
Product brochure
PDFAdditional information
Number of channels | 1 Channel |
---|---|
Measurement method | Direct flow measurement with flow sensors |
Working pressure | Standard: -1÷0 Bar (vacuum) — 0÷0.35 Bar — 0÷1 Bar — 0÷2 Bar — 0÷4 Bar — Other pressures on request |
Pressure measurement resolution | 1 mBar |
Non-linearity error in pressure measurement | Less than 0.3% |
Flow measurement range | Standard: 0 ÷ 50 ml/min, resolution 0.01 ml/min 0 ÷ 500 ml/min, resolution 0.1 ml/min 0 ÷ 5 l/min, resolution 0.001 l/min 0 ÷ 10 l/min, resolution 0.001 l/min 0 ÷ 50 l/min, resolution 0.01 l/min 0 ÷ 100 l/min, resolution 0.01 l/min 0 ÷ 400 l/min, resolution 0.1 l/min 0 ÷ 500 l/min, resolution 0.1 l/min Other measurement ranges on request |
Non-linearity error in flow measurement | Less than 1% |
Display | LED, 4¾ digits |
Programmable thresholds | Minimum – maximum pressure Minimum – maximum flow |
I/O signals | At PLC level, optoisolated, PNP 24 VDC IN: air supply command OUT: good, reject, pressure reject, flow reject |
Power supply | Standard: 100-240 VAC / 50-60 Hz |
Dimensions | 235 x 290 x 355 mm (W x H x D) |
Initial calibration | Carried out based on samples referred to national standards |
Warranty | 24 months |
Ask for information